Blodgett Boiler Hi Limit Switch: the steam generator safety has tripped

Behind the boiler probe there is a mechanical safety switch that trips at 248°F and must be reset by hand.

(844) 571-4566

Mon–Sat, 8am–8pm

  • Temperature and alarms
  • Reach-in and prep table repair
  • Source: Blodgett

Book a visit

Three short steps, about a minute.

or call (844) 571-4566

What Boiler Hi Limit Switch
actually means.

Behind the boiler probe there is a mechanical safety switch that trips at 248°F and must be reset by hand. When it opens, it signals the relay board and the control shows Boiler Hi Limit Switch. It usually follows low water, scale or a heater relay that did not release.

Blodgett commercial appliance display · also shown as Boiler Hi Limit Switch

What to do when Boiler Hi Limit Switch shows on the commercial appliance

Before you book,
in this order.

Each step comes from Blodgett's own guidance for Boiler Hi Limit Switch on its commercial appliances. Follow it to the end: the last card says whether this is a visit.

01

Turn the oven off and give the boiler time to cool.

02

Check the water supply, as a starved boiler is the usual cause.

03

Arrange service; the manual reset is behind panels and the cause has to be found first.

Still there?

It usually turns into reach-in and prep table repair. Book with the code and the model number.

What not to do

This message comes from the mechanical high limit, not the probe. A probe reading above 250°F appears as Boiler High Temp Error.

What you may
notice with it.

The commercial appliance problems Boiler Hi Limit Switch tends to arrive with. Answer these at the commercial appliance before anyone is booked.

All problems

Where Boiler Hi Limit Switch usually leads

Reach-in and prep table repair.

Reach-in, pass-through or prep table gasket, hinge, fan motor, thermostat or controller, defrost heater, leak repair or compressor · moderate.

In Blodgett's own words

The boiler manual reset high limit tripped and is sending a signal to the relay board. It trips at 248F.
Blodgett MenuSelect BC20 control service guide

Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. Blodgett BC-20 combi ovens with the MenuSelect control (MenuSelect BC20 service guide).

Blodgett Boiler Hi Limit Switch commercial appliance repair,
where we come out.

The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.

All service areas
A restaurant team working a busy commercial kitchen line.
For the heart of your home.

Questions
about Boiler Hi Limit Switch.

Can I clear Boiler Hi Limit Switch myself?
Turn the oven off and give the boiler time to cool. If it comes back, it needs a visit.
Where is the boiler high limit on a Blodgett combi?
On the boiler, behind service panels. Its reset is meant for a technician after the cause is found.
Why did my Blodgett boiler high limit trip after a water outage?
A boiler heating without water overheats fast. Restore water and have the limit reset and the heaters checked.
Is Boiler Hi Limit Switch the same as Boiler High Temp Error on a Blodgett?
No. One is the mechanical switch at 248°F; the other is the probe reading above 250°F.