What High Temp Error
actually means.
The high limit is a separate safety switch with its own manual reset. When the cavity passes 671°F, it sends a 24-volt signal to the relay board and the control shows High Temp Error. Blodgett's sheet sends the technician to three places: the heating contactor, the limit itself tripping too early, and the limit signal wire shorting.
Blodgett commercial appliance display · also shown as High Temp Error
What to do when High Temp Error shows on the commercial applianceKind of codeTemperature and alarms
The controller has seen a temperature outside the band it was set for and is saying so: a box above its alarm point, a fryer vat or an oven cavity that tripped its high-limit, or a dish machine rinse that never came up to heat. Often the cause sits outside the unit, such as a door left open during a delivery, a coil packed with grease, a kitchen far hotter than the maker allows or a booster fed cold water. Checking the door, the coil and the air around the unit is fair; move the product if a cold box stays above 41°F, and book the visit.
Usually leads toReach-in and prep table repair
Reach-ins, pass-throughs, prep tables and blast chillers: gaskets, hinges, fans, thermostats, condensers and compressors.
Shows up asCommercial Appliance Error Code on a Combi, Fryer, Dish Machine or Laundry Display
A commercial appliance error code appears as letters or numbers on a combi, fryer, reach-in controller, dish machine or laundry machine display, or as a flashing light or an alarm tone.
MakeBlodgett
A Blodgett visit tends to land early in the morning, before the first sheet pans go in and while the cavity is still cold.
SourceBlodgett combi and HydroVection control error codes service sheet
Listed on Blodgett's error codes service sheet for its combi and HydroVection electronic controls; the sheet does not name individual models.
Before you book,
in this order.
Each step comes from Blodgett's own guidance for High Temp Error on its commercial appliances. Follow it to the end: the last card says whether this is a visit.
End the cook and allow the oven to cool down, door shut.
Do not try to reach the high limit reset behind panels yourself.
Arrange a service call; the contactor, the limit and its signal wire all have to be tested before the oven heats again.
Still there?
It usually turns into reach-in and prep table repair. Book with the code and the model number.
What not to do
High Temp Error is not the same as Cavity High Temp Error, which comes from the cavity probe; this one comes from the independent limit switch. It can also appear without real overheating when the limit wire shorts, which is why testing matters.
What you may
notice with it.
The commercial appliance problems High Temp Error tends to arrive with. Answer these at the commercial appliance before anyone is booked.
All problemsWhere High Temp Error usually leads
Reach-in and prep table repair.
Blodgett
commercial appliances.
A Blodgett visit tends to land early in the morning, before the first sheet pans go in and while the cavity is still cold.
Blodgett commercial appliance repairMore Blodgett codes
Temperature and alarms on other makes
In Blodgett's own words
The High Limit (manual reset) reading exceeds 671˚F in the oven cavity
Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. Listed on Blodgett's error codes service sheet for its combi and HydroVection electronic controls; the sheet does not name individual models.
Blodgett High Temp Error commercial appliance repair,
where we come out.
The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.
All service areasTampa BayFL · 31 areas
Miami / South FloridaFL · 47 areas
New York MetroNY · 75 areas
HoustonTX · 36 areas
ChicagoIL · 50 areas
Los AngelesCA · 95 areas
San DiegoCA · 31 areas
Questions
about High Temp Error.
Can I clear High Temp Error myself?
Can staff reach the manual reset on a Blodgett combi high limit?
Can High Temp Error on a Blodgett happen without real overheating?
What temperature trips the Blodgett high limit?
Back to your everyday
Still showing High Temp Error?
A booking with a code goes further when it has the code as shown, the model and serial from the data plate, and a word on whether the unit still holds temperature, heats, rinses or spins. With those three, the office can match the likely part to your unit the same day.