The open door of a cold stainless combi oven in a commercial kitchen, its empty racks in view and a thin core temperature probe hanging on its holder inside the cavity, nobody at the combi oven.

Delfield E01: the air sensor is defective

Delfield's table names sensor 1 as the air sensor.

(844) 571-4566

Mon–Sat, 8am–8pm

  • Sensors and probes
  • Commercial controls and board repair
  • Source: Delfield

Book a visit

Three short steps, about a minute.

or call (844) 571-4566

What E01
actually means.

Delfield's table names sensor 1 as the air sensor. It is the one the control relies on to decide when to cool, so with E01 showing the cabinet temperature is no longer properly controlled.

Delfield commercial appliance display

What to do when E01 shows on the commercial appliance

Before you book,
in this order.

Each step comes from Delfield's own guidance for E01 on its commercial appliances. Follow it to the end: the last card says whether this is a visit.

01

Check the food with a separate thermometer and log it.

02

Move food that must stay at 41°F or below if the cabinet drifts.

03

Book a visit and mention E01.

Still there?

It usually turns into commercial controls and board repair. Book with the code and the model number.

What not to do

E01 is not a warm alarm, but a warm or overly cold cabinet may follow. E02 is the coil sensor, which affects defrost more than the cabinet temperature.

Where E01 usually leads

Commercial controls and board repair.

Controller, touch panel, probe or sensor, relay, contactor, power supply, door switch or interlock, tested before anything is changed · moderate.

In Delfield's own words

Sensor 1 defect E01 X Air sensor
Delfield 6000XL and 6100XL Series reach-ins, installation, operation and maintenance manual, part 9294254 (archived copy of the delfield.com PDF)

Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. Listed in the operation and indication table of Delfield's R290 reach-in manual (6000XL/6100XL) and prep table manual (4400/4500 Series).

Delfield E01 commercial appliance repair,
where we come out.

The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.

All service areas
A restaurant team working a busy commercial kitchen line.
For the heart of your home.

Questions
about E01.

Can I clear E01 myself?
Check the food with a separate thermometer and log it. If it comes back, it needs a visit.
What does E01 mean on a Delfield prep table?
The air sensor that the control uses to hold the cabinet has failed or lost its connection.
Can I keep a Delfield running with E01?
Only while you check the food with your own thermometer. Book a visit the same day.
Is E01 on a Delfield a control problem?
Usually it is the sensor or its wire. The control is checked too before any part is ordered.

Back to your everyday

Still showing E01?

A booking with a code goes further when it has the code as shown, the model and serial from the data plate, and a word on whether the unit still holds temperature, heats, rinses or spins. With those three, the office can match the likely part to your unit the same day.

(844) 571-4566 Schedule a repair