Delfield E02: the coil sensor is defective
Sensor 2 on Delfield's control reads the evaporator coil.
Mon–Sat, 8am–8pm
- Sensors and probes
- Commercial controls and board repair
- Source: Delfield
Book a visit
Three short steps, about a minute.
or call (844) 571-4566
Loading appointment form…
The appointment form couldn’t load. Please try again.
What E02
actually means.
Sensor 2 on Delfield's control reads the evaporator coil. The control uses it to end defrost and to hold the evaporator fans after defrost on low-temperature units. With E02 showing, defrost is no longer ended by coil temperature, and ice can build.
Delfield commercial appliance display
What to do when E02 shows on the commercial applianceKind of codeSensors and probes
A probe is handing the controller a reading it cannot trust, or none at all: a box or coil sensor torn loose from its clip, a fryer probe coated in carbon from oil left too long between filterings, a combi core probe with a kinked cable, or a connector gone green from steam and cleaning chemicals. The unit then runs on, stops, or shuts the heat or the cooling off to protect itself. Letting it cool and restarting it as the manual describes is fair; a probe that still reads wrong sits behind a panel, and that is a visit.
Usually leads toCommercial controls and board repair
Controllers, touch panels, relays, contactors and interlocks tested, and replaced only when the evidence says so.
Shows up asCommercial Appliance Error Code on a Combi, Fryer, Dish Machine or Laundry Display
A commercial appliance error code appears as letters or numbers on a combi, fryer, reach-in controller, dish machine or laundry machine display, or as a flashing light or an alarm tone.
MakeDelfield
For a Delfield station that runs warm by late lunch, we time the visit to a slow hour so the pans can come out and the rail can be tested empty.
SourceDelfield 6000XL and 6100XL Series reach-ins, installation, operation and maintenance manual, part 9294254 (archived copy of the delfield.com PDF)
Listed in the operation and indication table of Delfield's R290 reach-in manual (6000XL/6100XL) and prep table manual (4400/4500 Series).
Before you book,
in this order.
Each step comes from Delfield's own guidance for E02 on its commercial appliances. Follow it to the end: the last card says whether this is a visit.
Keep logging food temperatures.
Watch for frost building up behind the evaporator cover.
Book a visit before ice blocks the airflow.
Still there?
It usually turns into commercial controls and board repair. Book with the code and the model number.
What not to do
E02 is not the air sensor; E01 is. E03 and E04 in Delfield's table point to sensor inputs that are left open on these units.
What you may
notice with it.
The commercial appliance problems E02 tends to arrive with. Answer these at the commercial appliance before anyone is booked.
All problemsWhere E02 usually leads
Commercial controls and board repair.
Delfield
commercial appliances.
For a Delfield station that runs warm by late lunch, we time the visit to a slow hour so the pans can come out and the rail can be tested empty.
Delfield commercial appliance repairMore Delfield codes
Sensors and probes on other makes
Commercial cold storage
Reach-in and pass-through cabinets, walk-in coolers and walk-in freezers, prep and sandwich tables, undercounter units and blast chillers that hold a kitchen's food at safe temperatures.
Commercial cooking equipment
Fryers, griddles, charbroilers, restaurant ranges, convection and combi ovens, steamers, kettles, holding cabinets and toasters, on gas or electric, that make up the hot side of a kitchen line.
In Delfield's own words
Sensor 2 defect E02 X Coil sensor
Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. Listed in the operation and indication table of Delfield's R290 reach-in manual (6000XL/6100XL) and prep table manual (4400/4500 Series).
Delfield E02 commercial appliance repair,
where we come out.
The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.
All service areasTampa BayFL · 31 areas
Miami / South FloridaFL · 47 areas
New York MetroNY · 75 areas
HoustonTX · 36 areas
ChicagoIL · 50 areas
Los AngelesCA · 95 areas
San DiegoCA · 31 areas
Questions
about E02.
Can I clear E02 myself?
Why is my Delfield icing up with E02?
Is E02 on a Delfield urgent?
What are E03 and E04 on a Delfield?
Back to your everyday
Still showing E02?
A booking with a code goes further when it has the code as shown, the model and serial from the data plate, and a word on whether the unit still holds temperature, heats, rinses or spins. With those three, the office can match the likely part to your unit the same day.