Hobart 038: incoming power is too high

The LXn checks its supply voltage and shuts down when it is higher than the machine's rating, showing Incoming power to machine is too high with 038.

(844) 571-4566

Mon–Sat, 8am–8pm

  • Controls and power
  • Commercial controls and board repair
  • Source: Hobart

Book a visit

Three short steps, about a minute.

or call (844) 571-4566

What 038
actually means.

The LXn checks its supply voltage and shuts down when it is higher than the machine's rating, showing Incoming power to machine is too high with 038. Hobart asks for the breaker to be turned off and the supply checked against the data plate.

Hobart commercial appliance display · also shown as Error 038

What to do when 038 shows on the commercial appliance

Before you book,
in this order.

Each step comes from Hobart's own guidance for 038 on its commercial appliances. Follow it to the end: the last card says whether this is a visit.

01

Turn the machine's circuit breaker off.

02

Find the voltage on the machine's data plate and have an electrician measure the supply.

03

Once the supply is corrected, turn the breaker back on and press ENTER to clear the message.

04

Book a visit if 038 appears while the supply measures correct.

Still there?

It usually turns into commercial controls and board repair. Book with the code and the model number.

What not to do

038 is not a failed board, although a board that misreads voltage is possible when the supply tests fine. It is also different from a tripped breaker, which leaves the display dark rather than showing a code.

Where 038 usually leads

Commercial controls and board repair.

Controller, touch panel, probe or sensor, relay, contactor, power supply, door switch or interlock, tested before anything is changed · moderate.

In Hobart's own words

The incoming voltage must be at or below
Hobart LXn / LXGn series instructions manual F41243 (10-23), error code chart Hobart LXn / LXGn series instructions manual F41243 (10-23), error code chart

Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. Hobart LXn and LXGn undercounter machines (LXnC, LXnH, LXnR, LXGnPR, LXGnR) with the touchscreen control, per instructions manual F41243. AM16, CL and FT2000 machines use their own displays and are not covered by this chart.

Hobart 038 commercial appliance repair,
where we come out.

The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.

All service areas
A restaurant team working a busy commercial kitchen line.
For the heart of your home.

Questions
about 038.

Can I clear 038 myself?
Turn the machine's circuit breaker off. If it comes back, it needs a visit.
Why would a Hobart dish machine get too much voltage?
A machine wired to a different supply than its data plate, or a building supply running high, are the usual reasons. An electrician can confirm which.
Is 038 on a Hobart dangerous?
Powering down is the machine guarding its own electronics. A burning smell or brown marks near the power connection mean the breaker stays off until a technician has looked.
Does 038 clear by itself on a Hobart?
No. Once the supply is corrected, press ENTER to clear it.

Back to your everyday

Still showing 038?

A booking with a code goes further when it has the code as shown, the model and serial from the data plate, and a word on whether the unit still holds temperature, heats, rinses or spins. With those three, the office can match the likely part to your unit the same day.