Frymaster E19: the heat control latch did not hold on the FQ4000
When the FQ4000 calls for heat, a latch circuit and heat contactor have to close and stay closed.
Mon–Sat, 8am–8pm
- Controls and power
- Commercial controls and board repair
- Source: Frymaster
Book a visit
Three short steps, about a minute.
or call (844) 571-4566
Loading appointment form…
The appointment form couldn’t load. Please try again.
What E19
actually means.
When the FQ4000 calls for heat, a latch circuit and heat contactor have to close and stay closed. If that does not happen, the vat does not heat and the controller logs E19. Frymaster's troubleshooting table lists a gas valve left off, a failed controller, a failed transformer, a failed contactor or an open high-limit thermostat as causes.
Frymaster commercial appliance display · also shown as HEATING FAILURE, HEATING FAILURE – XXX F
What to do when E19 shows on the commercial applianceKind of codeControls and power
The controller itself is reporting trouble, or the supply behind it is: a display with dead segments, a keypad that stopped responding after steam or degreaser got behind it, relays that stick, stored recipes or cycles that vanished overnight, a blown control fuse, or one leg of a three-phase feed missing so half the heat or the pump is gone. A full power cycle at the breaker, done as the manual describes, clears a passing glitch; a code that returns, a scorched smell or any sign of moisture behind the panel means the breaker stays off, and that is a visit.
Usually leads toCommercial controls and board repair
Controllers, touch panels, relays, contactors and interlocks tested, and replaced only when the evidence says so.
Shows up asCommercial Appliance Error Code on a Combi, Fryer, Dish Machine or Laundry Display
A commercial appliance error code appears as letters or numbers on a combi, fryer, reach-in controller, dish machine or laundry machine display, or as a flashing light or an alarm tone.
MakeFrymaster
A Frymaster fryer is serviced cold: the visit waits until the oil has come down and the vat has been drained by the crew.
SourceFrymaster FilterQuick FQG30U easyTouch gas fryer manual with FQ4000 controller (error log codes, section 5.6)
FQ4000 easyTouch touchscreen controller on FilterQuick fryers (FQG30U and related FilterQuick gas and electric models). The same troubleshooting row covers E19 and E28 together.
Before you book,
in this order.
Each step comes from Frymaster's own guidance for E19 on its commercial appliances. Follow it to the end: the last card says whether this is a visit.
Check that the gas valve on the fryer is in the on position and that the gas quick-disconnect behind the fryer is fully seated, without loosening any fitting.
Power-cycle the controller once, pausing roughly sixty seconds between off and on; Frymaster notes this message can show at startup while air clears the gas lines.
If HEATING FAILURE returns with gas confirmed on, shut the vat down and have the contactor, transformer and high-limit circuit tested on a visit.
Still there?
It usually turns into commercial controls and board repair. Book with the code and the model number.
What not to do
E19 is about the heat circuit not engaging; E28 is the gas burner failing to light and the ignition module locking out. A slow climb to temperature with no error is a recovery problem (E44), not E19.
What you may
notice with it.
The commercial appliance problems E19 tends to arrive with. Answer these at the commercial appliance before anyone is booked.
All problemsWhere E19 usually leads
Commercial controls and board repair.
Frymaster
commercial appliances.
A Frymaster fryer is serviced cold: the visit waits until the oil has come down and the vat has been drained by the crew.
Frymaster commercial appliance repairMore Frymaster codes
All 15 Frymaster codesControls and power on other makes
In Frymaster's own words
Heating Control latch circuit failed.
Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. FQ4000 easyTouch touchscreen controller on FilterQuick fryers (FQG30U and related FilterQuick gas and electric models). The same troubleshooting row covers E19 and E28 together.
Frymaster E19 commercial appliance repair,
where we come out.
The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.
All service areasTampa BayFL · 31 areas
Miami / South FloridaFL · 47 areas
New York MetroNY · 75 areas
HoustonTX · 36 areas
ChicagoIL · 50 areas
Los AngelesCA · 95 areas
San DiegoCA · 31 areas
Questions
about E19.
Can I clear E19 myself?
Why does my Frymaster show HEATING FAILURE right after a filter cycle?
Is E19 a gas problem or an electrical one on a Frymaster?
Will a Frymaster with E19 heat at all?
Back to your everyday
Still showing E19?
A booking with a code goes further when it has the code as shown, the model and serial from the data plate, and a word on whether the unit still holds temperature, heats, rinses or spins. With those three, the office can match the likely part to your unit the same day.