Hoshizaki E3: an HPR prep table defrost ran past an hour

On HPR prep tables the display normally shows dF during defrost.

(844) 571-4566

Mon–Sat, 8am–8pm

  • Compressor and cooling
  • Walk-in cooler repair
  • Source: Hoshizaki

Book a visit

Three short steps, about a minute.

or call (844) 571-4566

What E3
actually means.

On HPR prep tables the display normally shows dF during defrost. If the coil has not warmed enough to end defrost within an hour, the control stops the defrost itself and raises E3, which may alternate with dF instead of the temperature. The usual suspects are the defrost heater and the defrost thermistor.

Hoshizaki commercial appliance display

What to do when E3 shows on the commercial appliance

Before you book,
in this order.

Each step comes from Hoshizaki's own guidance for E3 on its commercial appliances. Follow it to the end: the last card says whether this is a visit.

01

Turn the prep table off and back on, as Hoshizaki's table directs.

02

Watch whether the display returns to a temperature or goes back to dF and E3.

03

Check the cabinet with a thermometer over the next hour.

04

Book a visit so the defrost heater and defrost thermistor can be tested.

Still there?

It usually turns into walk-in cooler repair. Book with the code and the model number.

What not to do

dF by itself is the normal defrost display and only becomes a concern when E3 appears with it. E3 is not a warm-cabinet alarm, though a coil that never clears its ice will eventually let the cabinet warm.

Where E3 usually leads

Walk-in cooler repair.

Walk-in evaporator fan, defrost heater or drain line heater, door gasket, frame heater, expansion valve, leak repair, compressor or condensing unit · moderate to highest.

In Hoshizaki's own words

Cabinet defrost has taken longer than 1 hour. The control board has terminated defrost.
Hoshizaki HPR46A, HPR72A and HPR100A prep table service manual (archived copy of the Hoshizaki America PDF) Hoshizaki HPR46A, HPR72A and HPR100A prep table service manual (archived copy of the Hoshizaki America PDF)

Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. Older Hoshizaki HPR46A, HPR72A and HPR100A prep tables with raised rails, which use a two-character control different from the Steelheart display.

Hoshizaki E3 commercial appliance repair,
where we come out.

The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.

All service areas
A restaurant team working a busy commercial kitchen line.
For the heart of your home.

Questions
about E3.

Can I clear E3 myself?
Turn the prep table off and back on, as Hoshizaki's table directs. If it comes back, it needs a visit.
Why does my HPR show E3 and dF back and forth?
The control ended a defrost that ran past an hour and is flagging it. Restart the table; if the pair comes back at the next defrost, the heater or its sensor needs testing.
Does E3 mean the HPR prep table stopped cooling?
No, ending the long defrost lets cooling resume. The coil may still hold ice, so airflow can stay weak until the repair.
Will E3 return after a restart?
If the heater or the defrost thermistor has failed, usually yes, at the next scheduled defrost. That repeat is the sign to book a visit.

Back to your everyday

Still showing E3?

A booking with a code goes further when it has the code as shown, the model and serial from the data plate, and a word on whether the unit still holds temperature, heats, rinses or spins. With those three, the office can match the likely part to your unit the same day.