A gray electrical disconnect box on a tiled commercial kitchen wall beside a stainless convection oven, the oven's heavy power cord running up to it, the disconnect handle set to off, nobody near it.

Hoshizaki ULo: supply voltage too low for the prep table

The same voltage watch that raises UHi also catches a weak supply.

(844) 571-4566

Mon–Sat, 8am–8pm

  • Controls and power
  • Commercial controls and board repair
  • Source: Hoshizaki

Book a visit

Three short steps, about a minute.

or call (844) 571-4566

What ULo
actually means.

The same voltage watch that raises UHi also catches a weak supply. At roughly 96 volts or less the display shows ULo and the compressor is de-energized until the voltage recovers, when the safety resets itself.

Hoshizaki commercial appliance display

What to do when ULo shows on the commercial appliance

Before you book,
in this order.

Each step comes from Hoshizaki's own guidance for ULo on its commercial appliances. Follow it to the end: the last card says whether this is a visit.

01

Trace the prep table's cord and make sure it reaches a wall outlet directly, with no power strip or extension in between.

02

Note whether ULo appears when a nearby oven, mixer or dish machine starts.

03

Keep the lids closed and check rail pans with a thermometer while the compressor is off.

04

Have the circuit measured, and book a visit if ULo shows while the voltage is normal.

Still there?

It usually turns into commercial controls and board repair. Book with the code and the model number.

What not to do

ULo is not a failed compressor, even though the compressor stops. It is also unrelated to Lo, which means the cabinet is too cold.

Where ULo usually leads

Commercial controls and board repair.

Controller, touch panel, probe or sensor, relay, contactor, power supply, door switch or interlock, tested before anything is changed · moderate.

In Hoshizaki's own words

Low-Voltage Alarm (96VAC±5% or less)
Hoshizaki Steelheart prep table with raised rail and refrigerated equipment stand service manual (archived copy of the Hoshizaki America PDF) Hoshizaki Steelheart prep table with raised rail and refrigerated equipment stand service manual (archived copy of the Hoshizaki America PDF)

Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. Steelheart prep tables with raised rail and refrigerated equipment stands.

Hoshizaki ULo commercial appliance repair,
where we come out.

The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.

All service areas
A restaurant team working a busy commercial kitchen line.
For the heart of your home.

Questions
about ULo.

Can I clear ULo myself?
Trace the prep table's cord and make sure it reaches a wall outlet directly, with no power strip or extension in between. If it comes back, it needs a visit.
Can an extension cord cause ULo on a Hoshizaki prep table?
It can. A long or thin cord loses voltage under load, which is why cold storage belongs on its own properly sized outlet.
Will ULo damage the Hoshizaki compressor?
The control stops the compressor to prevent that. Repeated starts on a sagging supply are still hard on it, so find the cause rather than living with the code.
Why does ULo show whenever the dish machine runs?
Two heavy loads may share a circuit or a weak feed. An electrician can measure the drop while both are running and split them if needed.

Back to your everyday

Still showing ULo?

A booking with a code goes further when it has the code as shown, the model and serial from the data plate, and a word on whether the unit still holds temperature, heats, rinses or spins. With those three, the office can match the likely part to your unit the same day.

(844) 571-4566 Schedule a repair