Hoshizaki E1: an older HPR prep table has run warm

HPR46A, HPR72A and HPR100A prep tables use an earlier control with two-character codes that alternate with the temperature.

(844) 571-4566

Mon–Sat, 8am–8pm

  • Temperature and alarms
  • Reach-in and prep table repair
  • Source: Hoshizaki

Book a visit

Three short steps, about a minute.

or call (844) 571-4566

What E1
actually means.

HPR46A, HPR72A and HPR100A prep tables use an earlier control with two-character codes that alternate with the temperature. E1 is its cabinet high-temperature alarm: 18°F over the setpoint for longer than the set delay. It clears on its own when the cabinet returns to range.

Hoshizaki commercial appliance display

What to do when E1 shows on the commercial appliance

Before you book,
in this order.

Each step comes from Hoshizaki's own guidance for E1 on its commercial appliances. Follow it to the end: the last card says whether this is a visit.

01

Check the cabinet and the rail pans with a probe thermometer and move anything above 41°F.

02

Close the doors and drawers fully and keep the rail lid down between orders.

03

Clean the condenser air filter if it is dusty, as Hoshizaki's table advises.

04

Book a visit if the temperature does not start falling within an hour.

Still there?

It usually turns into reach-in and prep table repair. Book with the code and the model number.

What not to do

E1 on an HPR is not the E01 sensor code of the newer Steelheart control, even though the two look alike. The alarm reads the cabinet only; the rail is not part of it.

Where E1 usually leads

Reach-in and prep table repair.

Reach-in, pass-through or prep table gasket, hinge, fan motor, thermostat or controller, defrost heater, leak repair or compressor · moderate.

In Hoshizaki's own words

Cabinet temperature has exceeded the setpoint temperature by 18°F (10°C)
Hoshizaki HPR46A, HPR72A and HPR100A prep table service manual (archived copy of the Hoshizaki America PDF) Hoshizaki HPR46A, HPR72A and HPR100A prep table service manual (archived copy of the Hoshizaki America PDF)

Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. Older Hoshizaki HPR46A, HPR72A and HPR100A prep tables with raised rails, which use a two-character control different from the Steelheart display.

Hoshizaki E1 commercial appliance repair,
where we come out.

The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.

All service areas
A restaurant team working a busy commercial kitchen line.
For the heart of your home.

Questions
about E1.

Can I clear E1 myself?
Check the cabinet and the rail pans with a probe thermometer and move anything above 41°F. If it comes back, it needs a visit.
How long does an HPR prep table wait before showing E1?
Two hours by default. The delay can be set from none to three hours in the service menu, so a table that shows E1 quickly may simply have a shorter setting.
Does E1 on an HPR mean the rail is warm too?
Not by itself, since the alarm reads the cabinet. Check the rail pans anyway, because a dirty condenser warms both.
Is an HPR prep table too old to repair after E1?
Age alone does not decide it. Clean the condenser filter first; if E1 returns, a technician can tell whether the cause is a small part or the sealed system.

Back to your everyday

Still showing E1?

A booking with a code goes further when it has the code as shown, the model and serial from the data plate, and a word on whether the unit still holds temperature, heats, rinses or spins. With those three, the office can match the likely part to your unit the same day.