Rational Service 110: the steam generator pump stopped during cleaning

During an automatic clean the iCombi Pro also pumps water through the steam generator.

(844) 571-4566

Mon–Sat, 8am–8pm

  • Motors and drives
  • Commercial laundry machine repair
  • Source: Rational

Book a visit

Three short steps, about a minute.

or call (844) 571-4566

What Service 110
actually means.

During an automatic clean the iCombi Pro also pumps water through the steam generator. Service 110 reports an error in that pump during the run. Rational lists cooking as not possible afterward.

Rational commercial appliance display · also shown as 110

What to do when Service 110 shows on the commercial appliance

Before you book,
in this order.

Each step comes from Rational's own guidance for Service 110 on its commercial appliances. Follow it to the end: the last card says whether this is a visit.

01

Leave the door closed until the program has stopped and the cabinet has cooled; cleaning chemicals may still be inside.

02

Wear safety glasses and chemical-resistant gloves if you must open the door, and rinse any residue off skin with running water.

03

Book a visit, since the oven cannot cook until the pump is checked.

Still there?

It usually turns into commercial laundry machine repair. Book with the code and the model number.

What not to do

Service 110 is not the waste water pump, which is Service 47.1 and still allows cooking. It is also different from Service 120, which concerns water level detection during the same cleaning program.

Where Service 110 usually leads

Commercial laundry machine repair.

Laundry machine door lock, belt, bearings and seal, drain valve, inverter or motor; tumbler igniter, flame sensor, gas valve coil or airflow switch · moderate.

In Rational's own words

An error occurred in the SC pump during the automatic clean.
RATIONAL iCombi Pro floor units 20-1/1 and 20-2/1, original instructions for use (US English) RATIONAL iCombi Pro floor units 20-1/1 and 20-2/1, original instructions for use (US English)

Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. Listed in the error message tables of the iCombi Pro floor unit instructions for use (models 20-1/1 and 20-2/1, US English edition).

Rational Service 110 commercial appliance repair,
where we come out.

The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.

All service areas
A restaurant team working a busy commercial kitchen line.
For the heart of your home.

Questions
about Service 110.

Can I clear Service 110 myself?
Leave the door closed until the program has stopped and the cabinet has cooled; cleaning chemicals may still be inside. If it comes back, it needs a visit.
Is it safe to open my Rational after Service 110?
Wait until the cabinet is cool and wear eye protection and chemical gloves, because cleaner may still be inside. Rational warns that its cleaning chemicals can burn skin and eyes.
Why can't my Rational cook after Service 110?
Rational marks this message as no cooking possible. The steam generator pump has to be checked before the oven runs again.
Does hard water lead to Service 110 on a Rational?
Scale can make pumps and valves stick, which is why the care routine matters. The manual does not name the cause, so a technician will confirm it.

Back to your everyday

Still showing Service 110?

A booking with a code goes further when it has the code as shown, the model and serial from the data plate, and a word on whether the unit still holds temperature, heats, rinses or spins. With those three, the office can match the likely part to your unit the same day.

(844) 571-4566 Schedule a repair