Traulsen SN3: the liquid line sensor has failed

Traulsen's R & A Series controls read a third sensor on the liquid line of the cooling system, which the control lists as its own readout.

(844) 571-4566

Mon–Sat, 8am–8pm

  • Sensors and probes
  • Commercial controls and board repair
  • Source: Traulsen

Book a visit

Three short steps, about a minute.

or call (844) 571-4566

What SN3
actually means.

Traulsen's R & A Series controls read a third sensor on the liquid line of the cooling system, which the control lists as its own readout. SN3 says that sensor is no longer giving a valid reading. It is a service message.

Traulsen commercial appliance display

What to do when SN3 shows on the commercial appliance

Before you book,
in this order.

Each step comes from Traulsen's own guidance for SN3 on its commercial appliances. Follow it to the end: the last card says whether this is a visit.

01

Check that the cabinet is still holding temperature and log it.

02

Keep the condenser clean and the doors closed so the system is not stressed while you wait.

03

Book a visit and mention SN3.

Still there?

It usually turns into commercial controls and board repair. Book with the code and the model number.

What not to do

SN3 is not a refrigerant leak and not a cabinet temperature alarm. It concerns a sensor the control uses to watch the cooling side, so the box can still be cold.

What you may
notice with it.

The commercial appliance problem SN3 tends to arrive with. Answer these at the commercial appliance before anyone is booked.

All problems

Where SN3 usually leads

Commercial controls and board repair.

Controller, touch panel, probe or sensor, relay, contactor, power supply, door switch or interlock, tested before anything is changed · moderate.

In Traulsen's own words

SN3: Indicates liquid line sensor has failed.*
Traulsen All Series quick reference guide, owner's manual TR35924 rev. C (2015), linked from traulsen.com owner's manuals Traulsen All Series quick reference guide, owner's manual TR35924 rev. C (2015), linked from traulsen.com owner's manuals

Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. Shown by the control on R & A Series cabinets, as listed in Traulsen's quick reference guide TR35924 (rev. C, 2015). Units built after July 2025 carry the Smart Control, which keeps alarms in a menu instead (see PFA).

Traulsen SN3 commercial appliance repair,
where we come out.

The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.

All service areas
A restaurant team working a busy commercial kitchen line.
For the heart of your home.

Questions
about SN3.

Can I clear SN3 myself?
Check that the cabinet is still holding temperature and log it. If it comes back, it needs a visit.
Is my Traulsen still safe to use with SN3?
Often yes, as long as the food stays cold. Watch the log and book a visit so the sensor is replaced.
What does the liquid line sensor do on a Traulsen?
It gives the control a temperature reading from the cooling system itself, separate from the cabinet air and the coil.
Can I see the sensor readings on a Traulsen control?
Traulsen lists cabinet air, coil and liquid line sensor readouts in the customer access menu of R & A Series controls.