Henny Penny E-20A: the gas fryer's air pressure switch reads closed

Before lighting, the PFG 600 checks that its draft system is working.

(844) 571-4566

Mon–Sat, 8am–8pm

  • Ignition and gas
  • Commercial cooking line gas repair
  • Source: Henny Penny

Book a visit

Three short steps, about a minute.

or call (844) 571-4566

What E-20A
actually means.

Before lighting, the PFG 600 checks that its draft system is working. The air pressure switch should prove airflow only once the blower runs; if it already reads closed, the control will not start ignition and shows E-20A.

Henny Penny commercial appliance display

What to do when E-20A shows on the commercial appliance

Before you book,
in this order.

Each step comes from Henny Penny's own guidance for E-20A on its commercial appliances. Follow it to the end: the last card says whether this is a visit.

01

Press the Timer button once to let the control retry ignition, as the manual directs.

02

Make sure nothing is blocking the flue area at the back of the fryer.

03

If E-20A returns, book a visit; the air switch is behind panels on the gas train and is service work.

Still there?

It usually turns into commercial cooking line gas repair. Book with the code and the model number.

What not to do

E-20A is the switch reading closed too early; the opposite, a switch that never closes, is E-20B. Neither code means the gas has failed to light, which is E-20D.

Where E-20A usually leads

Commercial cooking line gas repair.

Cooking line pilot, thermocouple, burner or orifice, safety valve, griddle thermostat, regulator or quick-disconnect hose, leak-checked · low to moderate.

In Henny Penny's own words

Air pressure switch failure
Henny Penny FM05-011R operator manual, PFE 500 / PFE 561 / PFG 600 pressure fryers (C1000 and C8000 controls) Henny Penny FM05-011R operator manual, PFE 500 / PFE 561 / PFG 600 pressure fryers (C1000 and C8000 controls)

Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. Henny Penny PFG 600 gas pressure fryer with the C1000 or C8000 control (operator manual FM05-011R); not shown by the electric PFE models.

Henny Penny E-20A commercial appliance repair,
where we come out.

The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.

All service areas
A restaurant team working a busy commercial kitchen line.
For the heart of your home.

Questions
about E-20A.

Can I clear E-20A myself?
Press the Timer button once to let the control retry ignition, as the manual directs. If it comes back, it needs a visit.
What is the air pressure switch on a Henny Penny gas fryer?
It proves the draft fan is moving combustion air before the burner lights. A switch stuck closed would tell the control the fan is running when it may not be.
Can we keep retrying ignition on E-20A?
Henny Penny allows a retry with the Timer button. Repeated retries will not fix a stuck switch, so book a visit if it comes back.
Does E-20A happen on the electric Henny Penny models?
No. It applies only to gas models that use the draft fan and air switch.