What E-26
actually means.

On the electric PFE models the control watches element current. If current flows while heat should be off, a contactor or the board is stuck, and the fryer shows E-26. Henny Penny warns it can appear even with the power switch off, so the switch alone may not stop the heat.

Henny Penny commercial appliance display

What to do when E-26 shows on the commercial appliance

Before you book,
in this order.

Each step comes from Henny Penny's own guidance for E-26 on its commercial appliances. Follow it to the end: the last card says whether this is a visit.

01

Unplug the fryer or switch off its circuit breaker from a dry panel; the power switch alone may not stop the elements.

02

Keep watch on the oil and keep the Class K extinguisher at hand until it cools; if there is smoke or flame, use the suppression system and call 911.

03

Book a visit so the contactors and the control board can be checked before the fryer is used again.

Still there?

It usually turns into commercial controls and board repair. Book with the code and the model number.

What not to do

E-26 is heat locked on, which is more serious than current reading high (E-25) or low (E-27). It is not an oil overheat reading, though it can lead to one.

Where E-26 usually leads

Commercial controls and board repair.

Controller, touch panel, probe or sensor, relay, contactor, power supply, door switch or interlock, tested before anything is changed · moderate.

In Henny Penny's own words

Heat amps locked on
Henny Penny FM05-011R operator manual, PFE 500 / PFE 561 / PFG 600 pressure fryers (C1000 and C8000 controls) Henny Penny FM05-011R operator manual, PFE 500 / PFE 561 / PFG 600 pressure fryers (C1000 and C8000 controls) Henny Penny FM05-011R operator manual, PFE 500 / PFE 561 / PFG 600 pressure fryers (C1000 and C8000 controls)

Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. Henny Penny PFE 500 and PFE 561 electric pressure fryers with the C1000 or C8000 control (operator manual FM05-011R); electric models only.

Henny Penny E-26 commercial appliance repair,
where we come out.

The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.

All service areas
A restaurant team working a busy commercial kitchen line.
For the heart of your home.

Questions
about E-26.

Can I clear E-26 myself?
Unplug the fryer or switch off its circuit breaker from a dry panel; the power switch alone may not stop the elements. If it comes back, it needs a visit.
Why does a Henny Penny show E-26 with the switch off?
A contactor that has welded closed feeds the elements directly, bypassing the switch. That is why Henny Penny says to unplug it or turn off the breaker.
Is E-26 an emergency on a Henny Penny?
Treat it as one. Heat that cannot be switched off can drive the oil toward its smoke point, so cut the power at the breaker and watch the vat.
What gets replaced after E-26?
Usually a contactor, sometimes the control board. A technician checks both before the fryer goes back into service.