Henny Penny E-10: the fryer's high-limit safety has tripped
The high limit is a separate safety device that watches the shortening.
Mon–Sat, 8am–8pm
- Temperature and alarms
- Reach-in and prep table repair
- Source: Henny Penny
Book a visit
Three short steps, about a minute.
or call (844) 571-4566
Loading appointment form…
The appointment form couldn’t load. Please try again.
What E-10
actually means.
The high limit is a separate safety device that watches the shortening. If the oil ever passes its limit, it opens and shuts off the heat on its own, and it stays open until someone resets it by hand once the oil has cooled.
Henny Penny commercial appliance display · also shown as High limit trip
What to do when E-10 shows on the commercial applianceKind of codeTemperature and alarms
The controller has seen a temperature outside the band it was set for and is saying so: a box above its alarm point, a fryer vat or an oven cavity that tripped its high-limit, or a dish machine rinse that never came up to heat. Often the cause sits outside the unit, such as a door left open during a delivery, a coil packed with grease, a kitchen far hotter than the maker allows or a booster fed cold water. Checking the door, the coil and the air around the unit is fair; move the product if a cold box stays above 41°F, and book the visit.
Usually leads toReach-in and prep table repair
Reach-ins, pass-throughs, prep tables and blast chillers: gaskets, hinges, fans, thermostats, condensers and compressors.
Shows up asCommercial Appliance Error Code on a Combi, Fryer, Dish Machine or Laundry Display
A commercial appliance error code appears as letters or numbers on a combi, fryer, reach-in controller, dish machine or laundry machine display, or as a flashing light or an alarm tone.
MakeHenny Penny
Henny Penny equipment gets its visit once the unit is cool, any oil is down and the crew has logged the last load.
SourceHenny Penny FM05-011R operator manual, PFE 500 / PFE 561 / PFG 600 pressure fryers (C1000 and C8000 controls)
Henny Penny PFE 500 and PFE 561 electric and PFG 600 gas pressure fryers with the C1000 or C8000 control (operator manual FM05-011R).
Before you book,
in this order.
Each step comes from Henny Penny's own guidance for E-10 on its commercial appliances. Follow it to the end: the last card says whether this is a visit.
Stop cooking and let the shortening cool fully; if there is smoke or flame, use the hood suppression system and Class K extinguisher as trained and call 911.
After the oil is cool, the manual places a red reset button under the control panel behind the door; if nobody on shift has been shown how, book a visit instead.
If the high limit will not reset, or trips again, leave the fryer off and book a visit: the limit or the temperature control needs testing.
Still there?
It usually turns into reach-in and prep table repair. Book with the code and the model number.
What not to do
E-10 is the backup safety speaking, so something let the oil get hot enough to reach it; a probe reading high without a trip shows E-5. A drain valve left open stops heating too, but that shows E-15.
What you may
notice with it.
The commercial appliance problems E-10 tends to arrive with. Answer these at the commercial appliance before anyone is booked.
All problemsWhere E-10 usually leads
Reach-in and prep table repair.
Henny Penny
commercial appliances.
Henny Penny equipment gets its visit once the unit is cool, any oil is down and the crew has logged the last load.
Henny Penny commercial appliance repairMore Henny Penny codes
All 16 Henny Penny codesTemperature and alarms on other makes
In Henny Penny's own words
Allow oil to cool, and then reset the high limit by manually pushing up on the reset button.
Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. Henny Penny PFE 500 and PFE 561 electric and PFG 600 gas pressure fryers with the C1000 or C8000 control (operator manual FM05-011R).
Henny Penny E-10 commercial appliance repair,
where we come out.
The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.
All service areasTampa BayFL · 31 areas
Miami / South FloridaFL · 47 areas
New York MetroNY · 75 areas
HoustonTX · 36 areas
ChicagoIL · 50 areas
Los AngelesCA · 95 areas
San DiegoCA · 31 areas
Questions
about E-10.
Can I clear E-10 myself?
Where is the high-limit reset on a Henny Penny pressure fryer?
Is it safe to keep resetting E-10 on a Henny Penny?
What if the Henny Penny high limit will not reset?
Back to your everyday
Still showing E-10?
A booking with a code goes further when it has the code as shown, the model and serial from the data plate, and a word on whether the unit still holds temperature, heats, rinses or spins. With those three, the office can match the likely part to your unit the same day.